Intelligent Digital Laboratory Corrosion Salt Spray Environmental Test Corrosion Chamber
Brief Introduction:
ASTM B117 was the first internationally recognized salt spray standard, originally published in 1939. Other important relevant standards are ISO9227, JIS Z 2371 and ASTM G85.
Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable. Although there may be a weak correlation between the duration in salt spray test and the expected life of a coating in certain coatings such as hot dip galvanized steel, this test has gained worldwide popularity due to low cost and quick results.
Seawater Acidified Test (cyclic) can be used to test the relative resistance to corrosion of coated or uncoated aluminium alloys and other metals, when exposed to a changing climate of acidified synthetic seawater spray, followed by a high humidity, both at an elevated temperature.
This test is also referred to as a SWAAT test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 2 part repeating cycle. 30 minutes exposure to a continuous indirect spray of synthetic seawater solution, prepared in accordance with the requirements of the test standard and acidified (to pH 2.8 to 3.0) by the addition of acetic acid.
This spray is set to fall-out on to the specimens at a rate of 1.0 to 2.0ml/80 cm²/hour. This is followed by 90 minutes exposure to a high humidity climate of above 98%RH. The entire test cycle is at a constant chamber temperature of +49C (may be reduced to +24 to +35C for organically coated specimens). The number of cycle repeats and therefore the test duration is variable
Features:
1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Specifications:
Please Note Small Type of 60 and 90 do not meet standard of ASTM B117.
Model | HL-60-SS | HL-90-BS | HL-120-NS | HL-160-NS | HL-200-NS | ||
Model (Touch Screen) | HL-60-CS | HL-90-CS | HL-120-CS | HL-160-CS | HL-200-CS | ||
Interior dimensions (mm) | W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions (mm) | W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40 L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & humid. range | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PVC) | ||||||
Heater | Corrosion-resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT-100) | ||||||
Safety device | Over-temperature protection , leakage protection |
Note:
1. The above specifications are for reference only, the actual specifications for the main quotation.
2. Custom made is available according to customers’ special requirements
DongGuan Q1-Test Equipment Co., Ltd.
DongGuan Q1-Test Equipment Co., Ltd. was founded in year 2000,
located in DongGuan, a famous industrial city.
Mainly specialized in manufacturing, developing and marketing
various environmental testing equipment like programmable
temperature and humidity test chamber QTH series, walk-in
temperature and humidity test chamber, thermal shock test chamber
QT3 series, industrial drying oven, burn-in chamber, salt
spray/corrosion test chamber QCC series.
All the Q1-Test products conform the standards of GB, BS, IEC, CNS,
ASTM, ISO, JIS, DIN and other relevant international testing
standards.
Q1-Test product is widely used in the field of aerospace, military,
automotive components, optoelectronic, electronic parts,
communication, furniture, building materials, chemicals, paint,
inspection laboratory, research institutes and other high-tech
industries.
We have powerful ability to design, develop and manufacture custom
made products according to customer’s special applications, and
will go on enlarge our products line, provide professional
solutions, timely services and qualified products to feedback
customers’ kind support and trust.
We are also looking forward extensively and deeply work with customers to create brilliant future together.